Unit · AXIAL-PISTON MOTOR
A6VM160HA1T/60W-PPB027A-SR909429218
Axial piston motor Bosch Rexroth series A6VM, type code A6VM160HA1T/60W-PPB027A-S, material number R909429218. Nominal size: NG 160. Axial piston unit: bent-axis design, variable (A6V). Operating mode: motor (M). Control device: automatic control, high-pressure related with minimum pressure increase Δp ≤ approx. 10 bar (HA1). Override (only for HA): override, hydraulic, remote controlled, proportional (T). Direction of rotation: viewed on drive shaft variable (W). Drive shaft: parallel keyed shaft DIN 6885 (P). Mounting flange: ISO 3019-2 4-hole (B). Working port: SAE working ports A and B at side, opposite Flushing and boost-pressure valve, mounted 7 (027). Beginning of control: at Vg min (standard for HA) (A). Standard/special version: special version (-S).
- Number
- R909429218
- Type code
- A6VM160HA1T/60W-PPB027A-S
- Group
- A6VM 160
- Edition
- 06/2020
This parts list has no drawing.
| Pos. | Number | Name | Qty | Add to inquiry |
|---|---|---|---|---|
| 1 | R909417252 | ROTARY GROUP Assembly parts list →L | 1 | |
| 2 | R909429219 | CONTROL Assembly parts list →L | 1 | |
| 3 | R909420889 | FLUSH/BOOST PRESSURE VALVE Assembly parts list →L | 1 | |
| 5 | R909412645 | HOUSING | 1 | |
| 6 | R909921790 | CONTROL LENS | 1 | |
| 8 | R909151694 | SCREW PLUGD | 1 | |
| 98 | R902166034 | SEAL KIT | 1 |
Parameters from the type code
| Item | Meaning | Code |
|---|---|---|
| Axial piston unit | Bent-axis design, variable | A6V |
| Operating mode | Motor | M |
| Size (NG) | 160 | 160 |
| Control device | Automatic control, high-pressure related with minimum pressure increase Δp ≤ approx. 10 bar | HA1 |
| Override (only for HA) | Override, hydraulic, remote controlled, proportional | T |
| Direction of rotation | Viewed on drive shaft variable | W |
| Drive shaft | Parallel keyed shaft DIN 6885 | P |
| Mounting flange | ISO 3019-2 4-hole | B |
| Working port | SAE working ports A and B at side, opposite Flushing and boost-pressure valve, mounted 7 | 027 |
| Beginning of control | At Vg min (standard for HA) | A |
| Standard/special version | Special version | -S |