Set of 2 pumps:
1. Axial Piston Variable Pump A11VLO. Swashplate design, variable, nominal pressure 350 bar, maximum pressure 400 bar. With charge pump. Open circuit. Size, ≈ displacement Vg maks. 260 cm3. Control unit: power control with override Direction of rotation: clockwise (viewed from shaft end).
2. Axial piston variable pump A4VG. Geometric displacement 250 cm3. Proportional control, hydraulic, Pilot-pressure related p = 6 to 18 bar. Pressure cut-off. Mechanical stroke limiter, externally adjustable. Stroking chamber pressure port X3, X4. DA control valve, fixed setting. Series 3, index 2. Without integrated boost pump.
Return
The above diagrams belong to Rexroth
www.boschrexroth.com